Testing pile foundations
Contents |
[edit] Introduction
Pile foundations are deep foundations. They are formed by long, slender, columnar elements typically made from steel or reinforced concrete, or sometimes timber. A foundation is described as 'piled' when its depth is more than three times its breadth.
The bearing capacity of a pile is determined by several factors, including the size, shape and type of pile, as well as the particular soil properties. The calculation method that is used as a means of testing pile foundations depends upon the magnitude of the work involved, the soil type, and the engineer’s specification. Methods of calculation include:
- Dynamic pile formulae.
- Static formula.
- Test loading.
The integrity of, and presence of defects in, new and existing piles can be assessed by carrying out a pile integrity test.
[edit] Dynamic formulae
In mainly non-cohesive soils, dynamic formulae can be used to calculate the approximate bearing capacity of piles. These are based on assumptions, including:
- The resistance to being driven into the soil is determined from the energy delivered by the hammer together with the pile movement when struck by the hammer.
- Resistance to being driven into the soil is equal to the ultimate bearing capacity for static loads.
The basis of the formulae is that the ability to overcome the ground resistance to penetration is equated with the energy delivered by the hammer on impact. A factor of safety must be applied when the ultimate bearing capacity has been achieved, before calculating the safe working load. This can vary according to the pile’s permitted settlement rate at working load, which is determined by the pile size and the soil compressibility.
[edit] Static formulae
For non-cohesive soils, the static formulae that can be used to test piles include the standard penetration test and the cone penetration test.
The standard penetration test involves measuring the soil’s resistance to penetration under static or dynamic loading. For more information, see Standard penetration test.
The cone penetration test involves a cone enclosed in a tube. This is pushed into the soil, and measurements are taken of the forces that are required to independently advance the cone and tube. The resistance of the cone to being driven into the soil is taken as being equal to the ultimate bearing capacity.
Laboratory tests are more suitable for estimating the shear strength values of cohesive soils.
[edit] Test loading
It is advisable to test load at least one pile per scheme by forming a trial pile that is in close proximity but does not form part of the actual foundations. The pile should be overloaded by at least 50% of its working load and held for 24 hours. This provides a check on the ultimate bearing capacity of the pile as well as the workmanship involved in forming the pile.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Skills England publishes Sector skills needs assessments
Priority areas relating to the built environment highlighted and described in brief.
BSRIA HVAC Market Watch - May 2025 Edition
Heat Pump Market Outlook: Policy, Performance & Refrigerant Trends for 2025–2028.
Committing to EDI in construction with CIOB
Built Environment professional bodies deepen commitment to EDI with two new signatories: CIAT and CICES.
Government Grenfell progress report at a glance
Line by line recomendation overview, with links to more details.
An engaging and lively review of his professional life.
Sustainable heating for listed buildings
A problem that needs to be approached intelligently.
50th Golden anniversary ECA Edmundson apprentice award
Deadline for entries has been extended to Friday 27 June, so don't miss out!
CIAT at the London Festival of Architecture
Designing for Everyone: Breaking Barriers in Inclusive Architecture.
Mixed reactions to apprenticeship and skills reform 2025
A 'welcome shift' for some and a 'backwards step' for others.
Licensing construction in the UK
As the latest report and proposal to licence builders reaches Parliament.
Building Safety Alliance golden thread guidance
Extensive excel checklist of information with guidance document freely accessible.
Fair Payment Code and other payment initiatives
For fair and late payments, need to work together to add value.
Pre-planning delivery programmes and delay penalties
Proposed for housebuilders in government reform: Speeding Up Build Out.
High street health: converting a building for healthcare uses
The benefits of health centres acting as new anchor sites in the high street.
The Remarkable Pinwill Sisters: from ‘lady woodcarvers’ to professionals. Book review.
Skills gap and investment returns on apprenticeships
ECA welcomes new reports from JTL Training and The Electrotechnical Skills Partnership.
Committee report criticises UK retrofit schemes
CIOB responds to UK’s Energy Security and Net Zero Committee report.